$ cd ..
Stokes Number
Compute the ratio of particle response time to flow time scale.
visual calculatorTurbulence & Wall Modeling
Read the flow shape before trusting the number.
This page turns a CFD setup into regime, scale, and dominant-effect cues. Adjust the calculator below and compare the moving graphic with the computed result.
01
input scale
02
model
03
check
StokesparticlemultiphaseLagrangian
formula
KaTeX rendered
ASCII source
St = tau_p / tau_f = (rho_p d_p^2 / 18 mu) (U / L)St = τ_p / τ_f
0.7631
regime
Max clustering — inertial focus
Particles cluster at St ≈ 1
τ_p (particle time)
0.0076 s
τ_f (flow time)
0.0100 s
Re_p = 33.0 > 1 — Stokes drag assumption invalid. Use Schiller-Naumann or Haider-Levenspiel correction.
Stokes law valid for Re_p ≪ 1. τ_p = ρ_p d_p² / (18μ).