$ cd ..
Pump Affinity Laws
Compare flow, head, and power scaling from speed and impeller-diameter changes with visual bars.
visual calculatorTurbomachinery & Rotating Flow
Read the flow shape before trusting the number.
This page turns a CFD setup into regime, scale, and dominant-effect cues. Adjust the calculator below and compare the moving graphic with the computed result.
01
input scale
02
model
03
check
pumpaffinity lawsrotating machineryscaling
formula
KaTeX rendered
ASCII source
Q2/Q1 = (N2/N1)(D2/D1)^3, H2/H1 = (N2/N1)^2(D2/D1)^2, P2/P1 = (N2/N1)^3(D2/D1)^5flow
before0.080
after0.107
head / 100
before0.350
after0.622
power / 10000
before0.420
after0.996
N2/N1
1.3333
D2/D1
1.0000
Q2 (m3/s)
0.1067
H2 (m)
62.222
P2 (W)
9955.56
Affinity laws are first-pass similarity scalings. Cavitation, Reynolds effects, and off-design separation can break them.