~13 min read

A 9% Smaller Drag Coefficient Left the Droplet 35% Slower — Where the Distortion and Vaporization Corrections Attach

·7 min read

Three drag-coefficient models — rigid sphere, TAB distortion, and Renksizbulut-Yuen vaporization — run on the same droplet and compared by penetration.

Why a Raindrop Is Not Tear-Shaped — The Weber Number and TAB Breakup

·6 min read

The TAB oscillator breaks a drop once the deformation y crosses 1. Undamped, that peak is 2·We/24, so the critical Weber number lands on 12.